Incoming data has a problem with date range:
DTP*291*RD8*20200101-20180902~
i.e. end of range is after start of range.
When reporting this problem in 999, would it be allowed to specify CTX segment (Element Context) in addition to IK4 reporting the error to specify that element DTP02 was also used during verification process of data value?
for example:
IK4*3*1251*8*20200101-20180902~
CTX*SITUATIONAL TRIGGER*DTP*15**2*1250~
or should CTX be omitted altogether for this problem reporting?
The CTX cannot be sent because the situational rule for the CTX segment reads:
Required when the error identified in this IK4 loop was triggered by a situational requirement of the implementation guide and the error occurs at the element level. If not required by this implementation guide, do not send. Therefore the CTX cannot be used.